64 11 826

Replacing servodrive of recirculated air flaps
(A/C control)

Remove trim for instrument panel, bottom right.

Remove side carpet on right side of center console. 

Unclip lock (1).

Pull out servodrive (2) in direction of arrow and disconnect plug
connection (3). 

Installation:

If necessary, align shaft of recirculated air flaps to position of
servodrive.

RA  Replacing servodrive of recirculated air flaps (A/C control)

BMW AG - TIS

07.02.2013  03:37

Issue status (12/2007) Valid only until next DVD is issued