X Series E53 X5 4.6is (M62) OFFRD
13 53 240
Replacing complete injection pipe (M62)
Interrogate fault memory of DME control unit.
Switch off ignition.
Turn fasteners on acoustic cover 90
°
counterclockwise.
Remove acoustic cover.
Detach plug connections (1) of knock sensors from cable strips.
Detach plug (2) from electric changeover valve.
Detach plugs (3) of camshaft sensors from cable strips.
Remove sealing caps on cover of ignition coils on left.
Release nuts.
Remove cover on ignition coils on left.
RA Replacing complete injection pipe (M62)
BMW AG - TIS
10.02.2013 20:28
Issue status (12/2007) Valid only until next DVD is issued
Copyright