Unlock plug (1) and remove.
Note:
Grip at hexagon head (2) when removing pressure sensor.
Release hexagon screw connection (3) on pressure
accumulator.
Installation:
Secure position of pressure sensor and grip at hexagon head (2).
Tighten down hexagon screw connection (3).
Tightening torque 13 53 9AZ
.
Important!
EU4 only.
Reset quantity mean value adaptation with BMW diagnosis
system.
Now clear the fault memory.
Check system for leaks.
RA Removing and installing/replacing pressure sensor on pressure accumulator of fue
BMW AG - TIS
05.02.2013 02:43
Issue status (12/2007) Valid only until next DVD is issued