37 12 ...

Replacing lower vent line

Important!

Risk of damage!

Extreme cleanliness must be ensured in the connection area
of the vent lines during removal and installation. Even the
smallest of dirt particles can cause leakage in the air spring
system.

Necessary preliminary tasks:

Remove front right wheel arch cover (rear section).

Disconnect quick-connect couplings (1, 3).

Seal connections of air supply unit supply line and upper vent line
with sealing plugs.

Unclip lower vent line (2) and feed out.