X Series E70 X5 3.0Sd (M57T2) OFFRD
64 53 733
Replacing double pipe
Warning!
Risk of injury!
Refrigerant circuit is under high pressure!
Follow safety instructions for handling R 134a refrigerant .
Avoid contact with refrigerant and refrigerant oil.
Follow safety instructions for handling refrigerant oil.
Important!
Risk of damage!
Restart engine only when A/C system has been correctly
filled.
Follow instructions for opening and replacing parts in
refrigerant circuit!
If A/C system is opened for more than 24 hours:Replace
desiccant insert for A/C system
Necessary preliminary tasks:
•
Drawing off, evacuating and filling the A/C system are not
included in the time value given for this work operation
Release screw (1).
Installation:
Check that rubber seal is correctly seated.
Tightening torque 64 53 1AZ
.