Important!
Risk of damage to instrument panel trim (2) if it is pulled
away too forcefully.
Release screw (1).
Carefully pull instrument panel trim (2) away in direction of arrow
and feed out fan (3).
Disconnect plug connection (1).
Installation:
Make sure cover (2) is securely seated.
Replacement:
Disconnect plug connection (1) and release screws (2).
Remove controller for fan (3).
RA Removing and installing/replacing heater/air conditioner fan
BMW AG - TIS
07.02.2013 03:53
Issue status (12/2007) Valid only until next DVD is issued