64 51 525

Removing and installing or replacing
expansion valve

Warning!

Risk of injury!

Refrigerant circuit is under high pressure!

Follow safety instructions for handling R 134a refrigerant .

Avoid contact with refrigerant and refrigerant oil.

Follow safety instructions for handling refrigerant oil.

Important!

Risk of damage!

Restart engine only when A/C system has been correctly
filled.

Follow instructions for opening and replacing parts in
refrigerant circuit!

If A/C system is opened for more than 24 hours:Replace
desiccant insert for A/C system

Necessary preliminary tasks:

Remove double pipe

Drawing off, evacuating and filling the A/C system are not

included in the time value given for this work operation

Remove gasket (1).

Installation:

Observe direction arrows (2) without fail.

If necessary, replace damaged seal (1).