64 53 660

Replacing line from compressor to double
pipe

Warning!

Risk of injury!

Refrigerant circuit is under high pressure!

Follow safety instructions for handling R 134a refrigerant .

Avoid contact with refrigerant and refrigerant oil.

Follow safety instructions for handling refrigerant oil.

Important!

Risk of damage!

Restart engine only when A/C system has been correctly
filled.

Follow instructions for opening and replacing parts in
refrigerant circuit.

If A/C system is opened for more than 24 hours:

Replace desiccant insert for A/C system 

Necessary preliminary tasks:

Drawing off, evacuating and filling the A/C system are not

included in the time value given for this work operation

Release screw (1) and remove refrigerant line (2).

Installation:

Replace sealing ring and moisten with refrigerant oil.

Tightening torque 64 53 5AZ

.