X Series E70 X5 3.0Si (N52K) OFFRD
64 53 660
Replacing line from compressor to double
pipe
Warning!
Risk of injury!
Refrigerant circuit is under high pressure!
Follow safety instructions for handling R 134a refrigerant .
Avoid contact with refrigerant and refrigerant oil.
Follow safety instructions for handling refrigerant oil.
Important!
Risk of damage!
Restart engine only when A/C system has been correctly
filled.
Follow instructions for opening and replacing parts in
refrigerant circuit.
If A/C system is opened for more than 24 hours:
Replace desiccant insert for A/C system
Necessary preliminary tasks:
•
Drawing off, evacuating and filling the A/C system are not
included in the time value given for this work operation
Release screw (1) and remove refrigerant line (2).
Installation:
Replace sealing ring and moisten with refrigerant oil.
Tightening torque 64 53 5AZ
.
RA Replacing line from compressor to double pipe