X Series E83 X3 2.0d (N47) OFFRD
64 11 839
Replacing actuator drive of footwell flap
Necessary preliminary tasks:
•
Remove glovebox
Unhook adjusting lever (1).
Disconnect plug connection (1). Unlock actuator drive (2) and
feed out towards rear.
Installation:
If necessary, align shaft for footwell flap and drive (see
illustration).
RA Replacing actuator drive of footwell flap
BMW AG - TIS
06.02.2013 10:25
Issue status (12/2007) Valid only until next DVD is issued
Copyright
Page - 1 -