bmw Workshop Repair Guides

BMW Workshop Service and Repair Manuals

13 RA Replacing Actuator Drive Of Defrosting Flaps > < 11 RA Replacing Actuator Drive Of Ventilation Flaps
Page 1
background image

64 11 839

Replacing actuator drive of footwell flap

Necessary preliminary tasks:

Remove glovebox 

Unhook adjusting lever (1).

Disconnect plug connection (1). Unlock actuator drive (2) and
feed out towards rear.

Installation:

If necessary, align shaft for footwell flap and drive (see
illustration).

RA  Replacing actuator drive of footwell flap

BMW AG - TIS

06.02.2013  10:25

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 1 -