X Series E83 X3 2.0i (N46) OFFRD
64 53 702
Replacing line from evaporator to compressor
(N46)
Warning!
Risk of injury!
Refrigerant circuit is under high pressure!
Follow safety instructions for handling R 134a refrigerant .
Avoid contact with refrigerant and refrigerant oil.
Follow safety instructions for handling refrigerant oil.
Important!
Risk of damage!
Restart engine only when A/C system has been correctly
filled.
Follow instructions for opening and replacing parts in
refrigerant circuit.
If A/C system is opened for more than 24 hours:
Replace desiccant insert for A/C system
Necessary preliminary tasks:
•
Drawing off, evacuating and filling the A/C system are not
included in the time value given for this work operation
•
Remove microfilter housing
•
Remove auxiliary air pump
•
Remove intake filter housing
•
Drain coolant from radiator and if necessary detach water
hoses in working area
Release screw (1).
Tightening torque 64 53 2AZ
.
Remove refrigerant line and unclip from holder (2).
Installation:
Replace sealing rings and moisten with refrigerant oil.
Make sure refrigerant line is firmly seated in holder (2).
RA Replacing line from evaporator to compressor (N46)
BMW AG - TIS
08.02.2013 18:57
Issue status (12/2007) Valid only until next DVD is issued
Copyright
Page - 1 -