64 11 829

Replacing actuator drive of ventilation flaps

Necessary preliminary tasks:

Disconnect battery negative lead

Remove glovebox 

Partially remove fuse box

Disconnect plug connection (1). Unlock actuator drive (2) and
remove.

Installation:

If necessary, align shaft for defrosting flaps and drive (see
illustration).

RA  Replacing actuator drive of ventilation flaps

BMW AG - TIS

10.02.2013  06:47

Issue status (12/2007) Valid only until next DVD is issued