Replacement:

A normalization must be carried out in order to activate anti-
trapping protection. 

Operating sequence for normalization:

Open corresponding window completely.

Operate corresponding power window switch in "Close"

position (second switch stage).

Once the upper end position has been reached, hold power

window switch down for approx. 1 second more.

Normalization is thus completed.

Note:

Carry out function check (one-touch function, anti-trapping
protection and, if necessary, comfort function).