bmw Workshop Repair Guides

BMW Workshop Service and Repair Manuals

13 RA Replacing Servodrive Of Footwell Flap > < 11 RA Replacing Servodrive Of Ventilation Flaps
Page 1
background image

64 11 834

Replacing servodrive of stratification flap

Remove right glovebox with housing.

Remove heating duct for footwell on right.

Disconnect plug connection (1). 

Unclip servodrive (2) and pull out in direction of arrow. 

Installation:

If necessary, align shaft of ventilation flaps to position of
servodrive.

RA  Replacing servodrive of stratification flap

BMW AG - TIS

07.02.2013  05:29

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 1 -

13 RA Replacing Servodrive Of Footwell Flap > < 11 RA Replacing Servodrive Of Ventilation Flaps