Z Series E85 M roadst (S54) ROADST
12 42 510
Replacing battery positive lead (between
starter motor and B+ support point) (S54)
Read fault memory. Switch off ignition.
Follow instructions for disconnecting and connecting battery.
Disconnect battery negative lead from battery and lay to one side.
Remove reinforcement plate
Release nut, remove battery positive lead (1) from battery
positive terminal.
Tightening torque 12 42 1AZ
.
Unfasten nut.
Remove battery positive lead (1) from holder.
Note:
For a better overview, this work step is shown without the intake
air manifold and from above. Carry out the work from below.
Unfasten nut.
Installation:
Tightening torque, 12 41 4AZ.
Detach battery positive lead from starter motor and remove.
RA Replacing battery positive lead (between starter motor and B+ support point) (S5
BMW AG - TIS
06.02.2013 21:28
Issue status (12/2007) Valid only until next DVD is issued
Copyright