bmw Workshop Repair Guides

BMW Workshop Service and Repair Manuals

7 RA Replacing Safety Pressure Switch > < 6 RA Removing And Installing _ Replacing Drier Bottle For Air Conditioner
Page 2
background image

Note:

If the A/C system remains open for longer than one hour, the
refrigerant lines must be sealed off with seal plugs. 

In event of warranty application, seal line openings with plugs of
new dryer bottle.

Release screws (1).

Detach refrigerant lines (2) in direction of arrow and press slightly
to one side.

Installation:

Replace sealing rings.

Tightening torque = 20 Nm (64 53 1AZ)

.

Gently release screws (3).

Pull out dryer bottle for A/C system (4) towards top.

After installation:

Evacuate and fill A/C system

RA  Removing and installing / replacing drier bottle for air conditioner

BMW AG - TIS

16.02.2013  05:56

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 2 -

7 RA Replacing Safety Pressure Switch > < 6 RA Removing And Installing _ Replacing Drier Bottle For Air Conditioner