bmw Workshop Repair Guides

BMW Workshop Service and Repair Manuals

1 RA Removing And Installing_replacing Both Lambda Oxygen Control Sensors (N52)|Page 463 > < 1 RA Removing And Installing Or Replacing EGR Cooler (N47)|Page 460
Page 1
background image

11 78 513 

Removing and installing/replacing both
lambda oxygen control sensors (N52)

Special tools required:

11 4 260

Warning!

Scalding hazard!

Only perform these tasks after the exhaust system has cooled
down. 

Necessary preliminary tasks:

Remove exhaust system.

Installation:

If an oxygen sensor is to be reused, only apply a thin and uniform
coat of Never Seez Compound (refer to BMW Parts Service)
to thread.

The part of the oxygen control sensor which projects into the
exhaust system branch (sensor ceramic) must not be cleaned or
come into contact with lubricant. 

RA  Removing and installing/replacing both lambda oxygen control sensors (N52)

BMW AG - TIS

15.02.2013  16:56

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 1 -

1 RA Removing And Installing_replacing Both Lambda Oxygen Control Sensors (N52)|Page 463 > < 1 RA Removing And Installing Or Replacing EGR Cooler (N47)|Page 460