Disconnect plug connection for lambda control sensor.

Detach oxygen sensor (1) from cylinders 4 to 6 with special
tool 11 4 260 .

Oxygen sensor at cylinders 1 to 3 is accessible from above
without the exhaust system having to be removed.

Installation:

Cable colour black, cylinders 1 to 3.

Cable colour gray, cylinders 4 to 6.

Tightening torque: 11 78 1AZ

.

Assemble engine.

Check function of DME. 