bmw Workshop Repair Guides

BMW Workshop Service and Repair Manuals

2 RA Notes On Initializing Power Window Unit (from 04_2004)|Page 2359 > < 1 RA Overview Of Servodrives
Page 1
background image

67 62 ...

Notes on initializing power window unit (from
04/2004)

Warning!

Danger of injury!

There is no anti-trapping protection during initialization.

Note:

Cars built prior and up to 04/2004 have no anti-trapping protection
and on the passenger side no toll closing function.

Initialization is performed on the power window switch of the
relevant door.

Requirements for correct initialization:

Initialization with engine running

Convertible top, doors and windows closed

Initialization comprises:

Erasure of initialization

Reinitialization

An initialization must be performed:

In the event of malfunctions, e.g. no one-touch control

function, no opening or if available no comfort function is
possible

After the power window drive has been replaced

After work is carried out on the power window mechanism

After a power supply interruption, e.g. disconnection of the

battery or disconnection of the power supply to the door

After the door window glass has been removed and installed

or replaced

After adjustment work on the door window glass

After adjustment work on the convertible top

After replacement of seals

RA  Notes on initializing power window unit (from 04/2004)

BMW AG - TIS

16.02.2013  04:36

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 1 -

2 RA Notes On Initializing Power Window Unit (from 04_2004)|Page 2359 > < 1 RA Overview Of Servodrives