Erasure of initialization:

Open door window glass fully

Operate power window switch in "Open" position four times

within 10 seconds

This erases initialization of the power window, anti-trapping
protection and toll function are inactive.

Check whether one-touch control (toll) function is inactive,
otherwise repeat procedure.

 

Reinitialization:

Avoid a break between the two steps!

 

Open door window glass fully

Operate and hold power window switch in "Close" position

(second switch stage)

Once the upper end position has been reached, hold power

window switch in "Close" position for approx. 2 seconds
longer

 

Open door window glass fully

Operate and hold power window switch in "Close" position

(second switch stage)

Once the upper end position has been reached, hold power

window switch in "Close" position for approx. 2 seconds
longer

 

This completes initialization.

Note:

Carry out function check (one-touch control function, anti-trapping
protection and, if necessary, comfort function).

RA  Notes on initializing power window unit (from 04/2004)

BMW AG - TIS

16.02.2013  04:36

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 2 -