buick Workshop Repair Guides

Buick Workshop Service and Repair Manuals

A/T - Service Manual Procedure Update.|Page 4866 > < A/T - Service Manual Procedure Update.|Page 4863
Page 1
background image

Transmission Cooler: All Technical Service Bulletins
A/T - Service Manual Procedure Update.

Bulletin 87-7-3

Date

Oct. '86

Ref. No. 87-003-7
SUBJECT:

1987 SERVICE MANUAL PROCEDURE UPDATE. ALL THM TRANSMISSIONS/TRANSAXLES OIL COOLER FLUSHING PROCEDURE

MODELS AFFECTED: ALL MODELS

NOTE:

This bulletin supersedes all transmission oil cooler flushing information published prior to this date.

FIGURE 1 - COOLER FLUSHING TOOLS

Transmission oil cooler flushing must be performed whenever a transmission/transaxle is removed for service. It is essential to flush the oil cooler after
SRTA installation, major overhaul, if fluid contamination is suspected, or in any case of pump or torque converter replacement. A new, essential cooler
flushing tool, Kent-Moore Number J35944 (Refer to Figure 1), has been developed to properly flush the oil cooler and will be shipped to GM dealers by
December, 1986. Time allowance for performing the cooler flushing procedure will be included in specific 1987 Labor Time Guide operations. When
using 1986, and prior, Labor Time Guides, add 0.6 hours for cooler flushing to the recondition or SRTA replacement time allowances.
To ensure complete transmission/transaxle system service, it is recommended that the flush procedure be performed after the overhauled or replacement
assembly has been reinstalled in the vehicle.

The service procedure steps for oil cooler flushing are as follows:

EQUIPMENT AND MATERIALS NEEDED

Kent-Moore Cooler Flusher Tool, J35944 and biodegradable flushing solution* Measuring Cup (supplied with tool) Funnel Water Supply (hot water
recommended in all cases, if available) Water Hose (at least 5/8 inch diameter) Air Supply (with water and oil filter) Air Chuck (with clip if available)
Air Pressure Gage Oil Drain Container Five Gallon Pail (or larger, with lid) Eye Protection Rubber Gloves

*

Solution available by the gallon, J35944-20, or six-gallon case J35944-CSE.

A/T - Service Manual Procedure Update.|Page 4866 > < A/T - Service Manual Procedure Update.|Page 4863