Century V6-3.1L VIN J (2005)
Seals and Gaskets: Service and Repair
Exhaust Seal Replacement (3.1L)
Removal Procedure
1. Raise and support the vehicle. Refer to Vehicle Lifting.
2. Notice: Refer to Catalytic Converter Movement Notice in Service Precautions.
Important: Use caution handling the pipe that contains an oxygen sensor. Do not cut the wire. For removal or repositioning disconnect the
connector.
Remove the exhaust manifold pipe stud nuts from the exhaust manifold studs.
3. Important: Support the exhaust system where hangers are removed.
Remove the catalytic converter exhaust hangers.
4. Reposition the exhaust system.