Century V6-3.1L VIN J (2005)
Accumulator HVAC: Service and Repair
ACCUMULATOR REPLACEMENT
TOOLS REQUIRED
J 39400-A Halogen Leak Detector
REMOVAL PROCEDURE
1. Recover the refrigerant. Refer to Refrigerant Recovery and Recharging.
2. Remove the air cleaner assembly.
3. Loosen the accumulator hose nut (2) from the accumulator.
4. Disconnect the accumulator hose from the accumulator.
5. Remove the A/C compressor hose block fitting nut (1) from the accumulator.
6. Disconnect the A/C compressor hose from the accumulator.
7. Remove the accumulator bracket retaining bolt.
8. Remove the accumulator bracket bolt clamp.
9. Remove the accumulator from the mounting bracket.
INSTALLATION PROCEDURE