buick Workshop Repair Guides

Buick Workshop Service and Repair Manuals

HVAC System - Manual > < Air Temperature Actuator - Left|Page 7339
Page 1
background image

Air Door Actuator / Motor: Service and Repair
Recirculation Actuator

RECIRCULATION ACTUATOR REPLACEMENT

REMOVAL PROCEDURE

1. Remove the instrument panel compartment.
2. Remove the right instrument panel insulator.
3. Disconnect the vacuum line from the recirculation actuator.
4. Lift the retaining tab in order to release the recirculation actuator and slide the actuator off of the mounting bracket.

5. Disconnect the vacuum actuator plunger rod from the recirculation lever.
6. Remove the recirculation actuator.

INSTALLATION PROCEDURE

1. Install the recirculation actuator.
2. Connect the recirculation actuator plunger rod to the recirculation door, then extend the plunger.
3. Push the vacuum actuator toward the HVAC control module case to secure the retaining tab.

IMPORTANT:  During installation, ensure that the recirculation actuator retaining tab is positioned above the mating base on the HVAC control
module case.

4. Connect the vacuum harness connector to the recirculation actuator.

IMPORTANT:  Verify that the vacuum actuator pushrod is not binding on the recirculation lever.

5. Install the instrument panel compartment.
6. Install the right instrument panel insulator.

HVAC System - Manual > < Air Temperature Actuator - Left|Page 7339