Clock: All Technical Service Bulletins
Audio - Inoperative Radio/Erratic Clock Display

Bulletin:

85-9-11

Date:

Apr 1985

Ref. No..:  85-219-9
SUBJECT:

INOPERATIVE RADIO AND/OR ERRATIC CLOCK DISPLAY

MODELS AFFECTED:

1985 ELECTRA AND 1984 RIVIERA

Some early model 1985 Electra and 1984 Riviera equipped with cassette tape decks may experience a condition of an inoperative radio and/or erratic
clock display along with normal unaffected tape deck performance. This condition may be caused by an electrostatic discharge (ESD) inside the receiver.
Vehicles operated in areas of low humidity increase the possibility of this condition occuring. For this condition to occur, the tape unit must be in use and
the tape search feature activated.  If a sufficient static electricity charge is generated, it can discharge through the receiver microprocessor causing the
radio and/or clock display to be inoperative. The tape deck operation does not depend on the microprocessor and will remain operational after this
condition occurs.  This temporary disablement of the receiver microprocessor can be reversed by removing all voltage from the radio receiver, however,
the unit should be removed and sent to an authorized Delco Service Center for correction to prevent this condition from recurring.

To diagnose if an electrostatic discharge is the cause of the inoperative radio and/or erratic clock display, the following test should be used.

1.

Verify that the AM and FM bands of the receiver do not operate and that the cassette tape deck does operate correctly.

2.

Remove power to the radio for a minimum of 10 seconds by either disconnecting and reconnecting the negative battery cable with key off or
removing and reinstalling the clock fuse.

3.

Retest for AM and FM operation.  If the radio now operates, the electrostatic discharge condition has occurred. To prevent this condition from
recurring, the receiver must be removed and sent to a Delco Service Center along with a claim tab indicating that it was disabled by an electrostatic
discharge.

WARRANTY INFORMATION

Labor Operation:

T6119

Labor Hours:

0.4 for R&R receiver and test for ESD

Trouble Code:

92