Electra Park Avenue V6-231 3.8L VIN C SFI (1989)
Keyless Entry Transmitter: Technical Service Bulletins
Locks - Revised Remote Keyless Entry System Programming
Bulletin
89-8-6
Date
Dec. '88
Ref. No.
89-020-8
Corp. Ref. No.
808208
SUBJECT:
REMOTE KEYLESS ENTRY SYSTEM PROGRAMMING PROCEDURE AND DIAGNOSTIC NOTE CORRECTION
MODELS AFFECTED:
1989 ELECTRA/PARK AVENUES
NOTICE:
This bulletin supersedes infomation regarding programming procedures for the Remote Keyless Entry System Found in the Electra and LeSabre
Electrical Systems Manual.
This procedure should be followed when replacing keyless entry module or either transmitter:
1.
Leave the ignition key in the "off" position.
2.
Jumper program connector terminal A (Pnk) to terminal B (Blk/Yel) (Door locks will lock and unlock in approximately 2 seconds). See Figure 1.
3.
Press any button on one transmitter once. (Door locks will lock and unlock in approximately 2 seconds). This will program the first transmitter.
4.
Repeat Step 3 using the other transmitter. If only one transmitter is being used, disconnect jumper.
5.
Disconnect jumper from program connector.
NOTICE:
This infomation corrects the "Keyless Entry Module Input Test" found in the Electra and LeSabre Electrical Systems Manual.
TEST A:
Keyless Entry Module Input test must be done with both the blue and black connectors disconnected from the receiver module. All jumpering should be
done with the ignition key off. The note at pin E of connector C1 (Blue) should say: Jumpering to battery locks all doors except the driver's door.