buick Workshop Repair Guides

Buick Workshop Service and Repair Manuals

All Technical Service Bulletins for Memory Calibration Unit: > < MAP - Revised Chart C-1D, DTC's 33, 34, 63, 64|Page 2835
Page 1
background image

Memory Calibration Unit: Customer Interest
Engine - Extended Crank Cold, Starts After Key is Cycled

Bulletin  90-6E-8

Date  Feb. '90

Ref. No.  90-061-6E

Corp. Ref. No.  906508R

SUBJECT:

COLD ENGINE EXTENDED CRANK, BUT IF THE IGNITION KEY IS CYCLED, THE ENGINE WILL START.

MODELS AFFECTED:

SOME 1989 AND EARLY BUILT 1990 BUICK LESABRES, ELECTRAS, RIVIERAS AND REATTAS EQUIPPED
WITH THE 3800 ENGINE (VIN CODE C)

Some 1989 through early built 1990 LeSabres, Electras, Rivieras and Reattas equipped with the 3800 engine (VIN Code C), may exhibit a condition of a
cold engine extended crank, but if the ignition key is cycled, the engine will start.

If this condition is experienced on a vehicle with good fuel pressure and the basic engine controls and systems are performing properly, it may be
necessary to install a new service Mem-Cal with a recalibrated fuel multiplier ratio during cranking.

Service Mem-Cals are currently available from GMSPO.

IMPORTANT:

The new calibration Mem-Cals are curtently being used in production. Verify if this Mem-Cal is already installed by the Scanner
I.D.

Axle Option

*Scanner Mem-Cal

Code Located

I.D. If this

Service

Model

Axle

on Service

Mem-Cal is

Part

Year

Application

Ratio

Pts.I.D. Label

Installed

Number

89/90

FED LeSab./Elec

2.84

F17

8094

16148060

89/90

CAL LeSab./Elec

2.84

F17

7994

16148005

89/90

FED LeSab./Elec.

2.97

F79

8004

16148006

89/90

CAL LeSab./Elec.

2.97

F79

8014

16148007

89

FED Riv.

2.84

F17

1074

16141292

89

CAL Riv.

2.84

F17

1084

16141296

89

FED Riv./Reatta

2.97

F79

1094

16141300

89

CAL Riv./Reatta

2.97

F79

1104

16141305

90

FED Riv.

2.97

F79

8084

16148016

90

CAL Riv.

2.97

F79

7984

16148003

90

FED Reatta

2.97

F79

8064

16148013

90

CAL Reatta

2.97

F79

8074

16148015

WARRANTY INFORMATION

Labor Operation Number:

T5191

Labor Time:

.5 Hours

Trouble Code:

92

All Technical Service Bulletins for Memory Calibration Unit: > < MAP - Revised Chart C-1D, DTC's 33, 34, 63, 64|Page 2835