4. Connect the suction hose/pipe to the A/C compressor.
5. Install the suction hose/pipe bolt to the A/C compressor.
Tighten the bolt to 9 Nm (80 lb in).
6. Install the suction hose/pipe bracket and secure with nut (1).
7. Install the air cleaner outlet duct. Refer to Air Cleaner Outlet Duct Replacement (See: Filters/Air Cleaner Housing/Air Cleaner Fresh Air
Duct/Hose/Service and Repair).
8. Evacuate and recharge the refrigerant system. Refer to Refrigerant Recovery and Recharging (See: Heating and Air Conditioning/Service and
Repair/Procedures/Refrigerant Recovery and Recharging).
9. Leak test the fittings of the component using J 39400-A .