buick Workshop Repair Guides

Buick Workshop Service and Repair Manuals

Recalls:|10085D|Page 15861 > < Recalls:|10085D|Page 15859
Page 9
background image

Ensure that the appropriate wire colors match up (as noted in Step 4) when the connection is made between the seat airbag harness and body
harness.

10. Slide all four terminals (2) into the appropriate connector body as shown above. Install the blue terminal position assurance (TPA) devices onto

the connector ends.

11. Add NyoGel 760 Lubricant (dielectric lubricant), P/N 12377900 (in Canada, use P/N 10953529) (Saturn retailers, use P/N 12345579) to the

terminals on both sides of the connections.

12. Wrap Woven Polyester Electrical Tape (PET) (preferred) or equivalent anti-abrasion tape or electrical tape around the two exposed wires on the

body harness up to the back of the connector.

13. Reinstall the conduit on the seat airbag harness.
14. Repeat the above procedure on the passenger seat.

Reinstall Seats

1. Install both the driver and passenger seats. Refer to Front Seat Replacement - Bucket in SI.
2. Reconnect the seat to body harness connector and the seat airbag connector.

Reroute Harness and Secure Connector

Follow the procedure below to re-route and attach the harness connector to the body harness bundle:

1. The original seat airbag connector was attached with a clip to the bottom of the seat (2) as shown above.

2. Using two wire ties, secure the seat airbag connector to the seat wire bundle as shown. Ensure that there is enough slack for full range of motion of

the seat.

3. Inspect the wires through the full range of motion of the seat again as in Step 2. Ensure that the wires have been secured in an orientation that

allows full seat motion with adequate clearance to the connectors and sufficient slack in the wires.

4. Enable the SIR system. Refer to SIR Disabling and Enabling in SI.
5. Turn the ignition on and use the diagnostic tool to clear the SDM DTCs and verify that the issue has been corrected. If the code is still current,

refer to the appropriate diagnostic procedure found in SI.

Recalls:|10085D|Page 15861 > < Recalls:|10085D|Page 15859