6. Remove the CMP actuator solenoid valve bolt and valve (3).
7. Inspect the CMP actuator solenoid valve seal for damage and replace as necessary.

Installation Procedure

1. Inspect the CMP actuator solenoid valve seal for damage. Replace the seal if necessary.

Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners
requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use
paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint
clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid
damage to parts and systems.

2. Install the CMP actuator solenoid valve (3) and bolt.

Tighten the bolt to 10 Nm (89 lb in).