Enclave FWD V6-3.6L (2008)
1. Connect the EVAP canister purge tube quick connect fitting to the EVAP canister purge solenoid valve.
2. Position the EVAP canister purge solenoid valve bracket to the upper intake manifold.
Notice: Refer to Fastener Notice.
3. Install the EVAP canister purge solenoid valve bracket bolt.
Tighten the bolt to 10 N.m (89 lb in).
4. Connect the EVAP canister purge tube quick connect fitting to the upper intake manifold.