buick Workshop Repair Guides

Buick Workshop Service and Repair Manuals

Recalls:|10335B|Page 17007 > < Recalls:|10335B|Page 17005
Page 6
background image

The completed terminal and seal should appear as shown above (body harness connector shown).

Note
Avoid getting solder on the terminal end or overheating the terminal.

Warning

DO NOT use soldering equipment that is battery or electric powered. These types of soldering irons can induce voltage into the circuit, which may cause
inflator module deployment and/or damage to electrical components. Use only the EL-28125-5 Ultra Torch or another butane fueled soldering iron when
working on SIR circuits.

8. Solder all four terminals at the wire crimp.

9. Slide the two body harness terminals through the opening of the orange connector position assurance (CPA) (1).

Note
Ensure that the appropriate wire colors match up (as noted in Step 4) when the connection is made between the seat airbag harness and body
harness.

10. Slide all four terminals (2) into the appropriate connector body as shown above. Install the blue terminal position assurance (TPA) devices onto

the connector ends.

11. Add NyoGel 760 Lubricant (dielectric lubricant), P/N 12377900 (in Canada, use P/N 10953529) (Saturn retailers, use P/N 12345579) to the

terminals on both sides of the connections.

12. Wrap Woven Polyester Electrical Tape (PET) (preferred) or equivalent anti-abrasion tape or electrical tape around the two exposed wires on the

body harness up to the back of the connector.

13. Reinstall the conduit on the seat airbag harness.
14. Repeat the above procedure on the passenger seat.

Reinstall Seats

1. Install both the driver and passenger seats. Refer to Front Seat Replacement - Bucket in SI.
2. Reconnect the seat to body harness connector and the seat airbag connector.

Recalls:|10335B|Page 17007 > < Recalls:|10335B|Page 17005