buick Workshop Repair Guides

Buick Workshop Service and Repair Manuals

Choke Thermostat/Heater > < All Technical Service Bulletins for Choke Pull-off:|846C12
Page 2
background image

FIGURE 2 - VACUUM BREAK TESTING PROCEDURE

2.

Use hand-held vacuum pump to apply 15" Hg (51 kPa) vacuum to the vacuum break, (figure 2).

A.

The vacuum break plunger should move full travel. Apply finger pressure to plunger to see that it has moved through full travel. If not,
replace the vacuum break.

B.

The vacuum break diaphragm should hold vacuum for at least twenty seconds. If it does not, replace the vacuum break.

Choke Thermostat/Heater > < All Technical Service Bulletins for Choke Pull-off:|846C12