REMOVAL PROCEDURE

1. Turn the ignition OFF.
2. Remove the ECM bracket bolts and reposition the ECM bracket in order to provide access.

IMPORTANT: Do not remove the engine control module (ECM) from the ECM bracket.

Do not remove the ECM redundant ground wire from the ECM.

3. Remove the camshaft position (CMP) actuator valve electrical connector.

4. Remove the CMP actuator valve bolt.
5. Remove the CMP actuator valve.