buick Workshop Repair Guides

Buick Workshop Service and Repair Manuals

Flat Wire Repairs|Page 7153 > < Flat Wire Repairs|Page 7151
Page 4
background image

1. Install the ECM bracket, as necessary.

Notice:  Refer to Fastener Notice in Service Precautions.

2. Install the ECM bracket bolts.

Tighten the ECM bracket bolts to 10 N.m (89 lb in).

Notice:  In order to prevent any possible electrostatic discharge damage to the ECM, do not touch the connector pins.

3. Install the ECM.
4. Install the ECM bolts.

Tighten the ECM bolts to 10 N.m (89 lb in).

5. Install the ECM redundant ground and bolt to the ECM.

Tighten the ECM redundant ground wire bolt to 5 N.m (44 lb in).