buick Workshop Repair Guides

Buick Workshop Service and Repair Manuals

Fuel Pump > < Metal Collar Quick Connect Fitting Service|Page 9179
Page 2
background image

1. Apply a few drops of clean engine oil to the male pipe end.

2. Push both sides of the quick-connect fitting together to cause the retaining tabs/fingers to snap into place.

3. Pull on both sides of the quick-connect fitting to make sure the connection is secure.
4. Inspect for leaks using the following procedure:

1. Turn the ignition ON, with the engine OFF for 2 seconds.
2. Turn the ignition OFF, for 10 seconds.
3. Turn the ignition ON, with the engine OFF for 2 seconds.
4. Turn the ignition OFF.
5. Inspect for leaks.

Fuel Pump > < Metal Collar Quick Connect Fitting Service|Page 9179