Shift Solenoid: Diagnostic Aids
Testing for a Short to Voltage

Testing for a Short to Voltage

Notice:  refer to Test Probe Notice.

The following procedure tests for a short to voltage in a circuit.

1.  Set the rotary dial of the DMM to the V (DC) position.
2.  Connect the positive lead of the DMM to one end of the circuit to be tested.
3.  Connect the negative lead of the DMM to a good ground.
4.  Turn ON the ignition and operate all accessories.
5.  If the voltage measured is greater than 1 volt, there is a short to voltage in the circuit.