8. Connect the heated oxygen sensor connector (2) to the rear of the throttle body heater inlet hose/pipe (3).
9. Install the wiper motor module.

10. Install the remote power steering fluid reservoir mounting bolts (1, 3).

^

Tighten the remote power steering fluid reservoir to intake plenum mounting bolts to 9 Nm (80 inch lbs.).

^

Tighten the remote power steering fluid reservoir to cylinder head mounting bolt to 25 Nm (18 ft. lbs.).

11. Connect the following to the remote power steering fluid reservoir (1):

^

The brake booster hose

^

The wiring harness (2)

12. Fill the cooling system. Refer to Draining and Filling Cooling System (L26 Static Fill) Draining and Filling Cooling System (LY7 Static Fill)

Draining and Filling Cooling System (L26, LY7, GE 47716 Fill) .