buick Workshop Repair Guides

Buick Workshop Service and Repair Manuals

Air Inlet Valve Actuator Replacement|Page 8878 > < Mode Valve Assembly Replacement|Page 8875
Page 1
background image

Air Door Actuator / Motor: Service and Repair
Air Inlet Valve Actuator Replacement

Air Inlet Valve Actuator Replacement

Removal Procedure

1. Remove the right instrument panel (I/P) insulator. Refer to Instrument Panel Insulator Panel Replacement - Right Side   (See: Body and

Frame/Interior Moulding / Trim/Dashboard / Instrument Panel/Service and Repair).

2. Remove the I/P compartment. Refer to Instrument Panel Compartment Replacement   (See: Body and Frame/Interior Moulding / Trim/Glove

Compartment/Service and Repair).

3. Remove the screws that secure the recirculation actuator to the HVAC module assembly.
4. Remove the recirculation actuator from the HVAC module assembly.
5. Disconnect the electrical connector from the recirculation actuator.

Installation Procedure

1. Position the recirculation actuator, aligning the slots in the electric actuator drive to the flats on the shaft.
2. Align the locating hole to the alignment pin on the HVAC module assembly.
3. Slide the actuator drive completely onto the shaft, with the mounting holes flush with the mounting screw holes on the HVAC module assembly.

Air Inlet Valve Actuator Replacement|Page 8878 > < Mode Valve Assembly Replacement|Page 8875