Pedal Positioning Sensor: Service and Repair
Brake Pedal Position Sensor Calibration

BRAKE PEDAL POSITION SENSOR CALIBRATION

CALIBRATION CRITERIA

The brake pedal position sensor receives a low reference signal and a 10-volt reference signal from the body control module (BCM). Whenever the
brake pedal is applied, the brake pedal position sensor applies a variable voltage signal to the BCM through the stop lamp switch signal circuit. Brake
pedal position sensor calibration must be performed after the brake pedal position sensor or BCM have been serviced. The calibration procedure will
set brake pedal position sensor home value. This value is used by the BCM to determine the action of the driver applying the brake system and to
provide this information to the vehicle subsystems via the class 2 communication bus.

CALIBRATION PROCEDURE

1. Turn ON the ignition, with the engine OFF.
2. Install a scan tool, select the proper vehicle and options.
3. Navigate to the BCM menu.
4. Select Special Functions menu item.
5. Select the BPPS sensor calibration procedure and follow the directions displayed on the screen.