14. Connect the fuel injector electrical connectors (1, 2).
15. Connect the main ignition coil harness electrical connector (4).
16. Install the CPA retainer (3).

17. Connect the generator electrical connector (2).

18. Connect the following electrical connectors:

*

EVAP purge solenoid (1)

*

MAP sensor (2)

*

ETC (3)

*

Oil pressure sensor (4)

*

Valve lifter oil manifold (5)

19. Install the air cleaner outlet duct. Refer to Air Cleaner Resonator Outlet Duct Replacement  (See: Air Cleaner Housing/Air Cleaner Fresh Air

Duct/Hose/Service and Repair).

20. Connect the negative battery cable. Refer to Battery Negative Cable Disconnection and Connection (LS4)  (See: Starting and

Charging/Battery/Battery Cable/Service and Repair).

21. Use the following steps to inspect for leaks:

1. Turn the ignition ON, with the engine OFF, for 2 seconds.
2. Turn the ignition OFF for 10 seconds.
3. Turn the ignition ON with the engine OFF.
4. Inspect for leaks.

22. Install the engine sight shield. Refer to Upper Intake Manifold Sight Shield Replacement  (See: Engine, Cooling and Exhaust/Engine/Intake

Manifold/Service and Repair).