Information Bus: Diagnostic Aids
Splicing Copper Wire Using Splice Sleeves

Splicing Copper Wire Using Splice Sleeves

Special Tools

*

EL-38125-10 - Splice Sleeve Crimping Tool

*

J 38125-5 - Ultra Torch

*

DuraSeal splice sleeves, in order to repair the SIR/SRS wiring

For equivalent regional tools, refer to Special Tools   (See: Power and Ground Distribution/Tools and Equipment).

Note:  Use only DuraSeal splice sleeves. Other splice sleeves may not protect the splice from moisture or provide a good electrical connection.

Use DuraSeal splice sleeves to form a one-to-one splice on all types of insulation except Tefzel and coaxial. Use DuraSeal splice sleeves where there is
special requirements such as moisture sealing. Follow the instructions below in order to splice copper wire using DuraSeal splice sleeves.

Note:  You must perform the following procedures in the listed order. Repeat the procedure if any wire strands are damaged. You must obtain a
clean strip with all of the wire strands intact.

1. Open the harness by removing any tape:

*

Use a sewing seam ripper, available from sewing supply stores, in order to cut open the harness in order to avoid wire insulation damage.

*

Use the DuraSeal splice sleeves on all types of insulation except Tefzel and coaxial.

*

Do not use the crimp and DuraSeal splice sleeve to form a splice with more than 2 wires coming together.

2. Cut as little wire off the harness as possible. You may need the extra length of wire in order to change the location of a splice.

Adjust splice locations so that each splice is at least 40 mm (1.5 in) away from the other splices, harness branches, or connectors.

3. Strip the insulation:

*

When adding a length of wire to the existing harness, use the same size wire as the original wire.

*

Perform one of the following items in order to find the correct wire size:

-

Find the wire on the schematic and convert to regional wiring gauge size. 

-

If you are unsure of the wire size, begin with the largest opening in the wire stripper and work down until achieving a clean strip of the
insulation.

*

Strip approximately 7.5 mm (0.313 in) of insulation from each wire to be spliced.

*

Do not nick or cut any of the strands. Inspect the stripped wire for nicks or cut strands.

*

If the wire is damaged, repeat this procedure after removing the damaged section.

4. For high temperature wiring, slide a section of high temperature SCT1 shrink tubing down the length of wire to be spliced. Ensure that the shrink

tubing will not interfere with the splice procedure.

5. Select the proper DuraSeal splice sleeve according to the wire size. Refer to the above table at the beginning of the repair procedure for the color

coding of the DuraSeal splice sleeves and the crimp tool nests.

Circuit Protection - Circuit Breakers|Page 2575 > < Circuit Protection - Circuit Breakers|Page 2573