3. Verify that a test lamp does not illuminate between the control circuit terminal 30 and ground. 

‹› If the test lamp illuminates, test the control circuit for a short to voltage.

4. Ignition ON, verify that a test lamp illuminates between the ignition circuit terminal 85 and ground.

‹› If the test lamp does not illuminate, test the ignition circuit for a short to ground or an open/high resistance.

5. Verify that a test lamp illuminates between the B+ circuit terminal 87 and ground.

‹› If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. If the circuit tests normal and the B+

circuit fuse is open, test the control circuit terminal 30 for a short to ground.

6. Disconnect the harness connector at an inoperative X80 accessory power receptacle.
7. Test for less than 10 ohm between the X80 accessory power receptacle ground circuit terminal C and ground.

‹› If greater than the specified range, test the ground circuit for an open/high resistance.

8. Connect the harness connector at the X80 accessory power receptacle.
9. Connect a 20 A fused jumper wire between the K10 accessory relay B+ circuit terminal 87 and the control circuit terminal 30. Verify the 12 V DC

accessory has power.

‹› If the 12 V DC does not have power, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, test or

replace the X80 accessory power receptacle.

10. If all circuits test normal, test or replace the K10 accessory relay.

Component Testing

Relay Test

1. Ignition OFF, disconnect the K10 accessory relay. 
2. Test for 60-180 ohm between terminals 85 and 86. 

‹› If not within the specified range, replace the relay.

3. Test for infinite resistance between the following terminals: 

*

30 and 86

*

30 and 87

*

30 and 85

*

85 and 87

‹› If not the specified value, replace the relay.

4. Install a 20 A fused jumper wire between relay terminal 85 and 12 V. Install a jumper wire between relay terminal 86 and ground. Test for less

than 2 ohm between terminals 30 and 87. 

‹› If greater than specified range, replace the relay.

Repair Instructions

Perform the Diagnostic Repair Verification   (See: Powertrain Management/Computers and Control Systems/Testing and Inspection/Diagnostic Trouble
Code Tests and Associated Procedures/Verification Tests and Procedures) after completing the diagnostic procedure.

*

Accessory Power Receptacle Replacement   (See: Service and Repair/Accessory Power Receptacle Replacement)

*

Relay Replacement (Attached to Wire Harness)   (See: Power Distribution Relay/Service and Repair/Relay Replacement (Attached  to Wire
Harness))Relay Replacement (Within an Electrical Center)   (See: Power Distribution Relay/Service and Repair/Relay Replacement (Within an
Electrical Center))

Symptoms - Power Outlets|Page 4860 > < Symptoms - Power Outlets|Page 4858