buick Workshop Repair Guides

Buick Workshop Service and Repair Manuals

Circuit Protection - Circuit Breakers|Page 8253 > < Circuit Protection - Circuit Breakers|Page 8251
Page 1
background image

Auxiliary Power Outlet: Diagnostic Aids
High Temperature Wiring Repairs

High Temperature Wiring Repairs

Special Tools

*

EL-38125-10 - Splice Sleeve Crimping Tool

*

J 38125-5 - Ultra Torch

*

DuraSeal splice sleeves, in order to repair the SIR/SRS wiring

For equivalent regional tools, refer to Special Tools   (See: Tools and Equipment).

High Temperature Wiring

Wiring that is exposed to high temperatures, 135°C (275°F) or higher, for prolonged periods of time may use materials i.e. wires, connectors, and
shielding that has a higher heat rating than typical wiring. When making a repair in a high temperature area observe the following:

*

Use high temperature bulk wire rated at 150°C (302°F) continuous temperature to replace any damaged wire.

*

Replace any heat shielding that is removed.

*

Cover any DuraSeal splice sleeves with SCT1 shrink tubing.

*

After making a wiring repair, ensure that the location of the wiring is not moved closer to the heat source.

Identifying High Temperature Wiring

Wiring that is exposed to high temperature, 135°C (275°F) or higher, for prolonged periods of time need special considerations when making wiring
repairs. Areas that may be exposed to higher temperatures can be identified by heat resistant materials that are being used in those areas. These materials
may include heat reflective tape, moon tape, and high temperature shrink tubing. Also conduit and other protective coverings may be used. Because
conduit or similar coverings are used throughout the vehicle regardless of the temperature, it may be necessary for the technician to determine if an area
is exposed to excessive heat before making a wiring repair. Obvious areas of consideration would be any area located near the exhaust manifolds,
catalytic converter, and exhaust pipes. 

Items Required

*

DuraSeal splice sleeves to crimp and seal connections

*

High temperature SCT1 shrink tubing to protect the splice sleeves

*

Terminated leads or pigtails

*

The correct tools to remove the terminals from the connectors

Use high temperature bulk wire rated at 150°C (302°F) continuous temperature of the same or larger gauge size as the original wire when repair damage
wire. Also replace any reflective tape that you remove during the repair. 

High Temperature Wire Repair

Note:  Refer to Wiring Repairs   (See: Testing and Inspection/Component Tests and General Diagnostics/Wiring Repairs/Wiring Repairs) in order to
determine the correct wire size for the circuit you are repairing. You must obtain this information in order to ensure circuit integrity.

If any wire except the pigtail is damaged, repair the wire by splicing in a new section of wire rated at 150°C (302°F) continuous temperature rating of the
same gauge size (0.5 mm, 0.8 mm, 1.0 mm etc.). Use the DuraSeal splice sleeves and the EL-38125-10 - tool and then encapsulate the splice sleeve using
the high temperature SCT1 shrink tubing. Use the following wiring repair procedures in order to ensure the integrity of the sealed splice.

Note:  You must perform the following procedures in the listed order. Repeat the procedure if any wire strands are damaged. You must obtain a