buick Workshop Repair Guides

Buick Workshop Service and Repair Manuals

All Technical Service Bulletins for Vacuum Harness HVAC: > < A/C System - Refrigerant Loss Prevention|Page 6510
Page 1
background image

Vacuum Harness HVAC: Customer Interest
A/C - Restricted Air Flow/Slow Mode Change to Defroster

Bulletin   

86-1-5

Date

June, '86

Ref. No. 86-123-1
SUBJECT:

RESTRICTED AIR FLOW OR SLOW MODE CHANGE TO DEFROSTER

MODELS AFFECTED: 1986 ELECTRA AND LESABRE WITH AIR CONDITIONING (C60)

A condition may occur on some 1986 manual air conditioned equipped Electra and LeSabres built prior to April, 1986, in which the instrument panel
lower sound insulator, in the installed position, could kink the vacuum supply line at the lower mode door actuator. The result could be reduced defroster
air flow or a slow mode change.

To correct, reroute vacuum line (red) over top of lower mode door actuator instead of underneath.

All Technical Service Bulletins for Vacuum Harness HVAC: > < A/C System - Refrigerant Loss Prevention|Page 6510