LeSabre V6-231 3.8L VIN L SFI (1992)
2.
Remove terminal *1/**3O and wire (circuit *5O/**41) from underhood fuse block (see illustration).
3.
Cut terminal off wire and tape back harness.
4.
Strip circuit *1444/**442 in an area to allow for splicing.
5.
Splice a wire into circuit *1444/**442 using splice clip, P/N 1839906, which can be found in terminal repair kit (J 38125). Follow the procedure
for splicing copper wire using splice clips in the Service Manual.
6.
Attach terminal to other end of wire and insert into underhood fuse block terminal *1/**3O.
7.
Reinstall blower speed relay in underhood fuse block.
PARTS INFORMATION
Parts are currently available from GMSPO.
WARRANTY INFORMATION