LeSabre V6-3.8L VIN K (1996)
Air Door Actuator / Motor: Adjustments
Electronic A/C System (RPO C67 and C68)
TEMPERATURE VALVE LINK ADJUSTMENT
1. Pull valve link from retainer on programmer output crank (if not previously disassembled).
2. Start vehicle; set temperature to 33°C (90°F).
3. Allow 45 seconds minimum for programmer motor to move output crank to its full hot position. Then move temperature valve to full hot position;
snap valve link into retainer on output crank.