buick Workshop Repair Guides

Buick Workshop Service and Repair Manuals

Exhaust Crossover Pipe > < Exhaust System - Catalytic Converter Precautions|Page 6487
Page 4
background image

7. Important:  A special anti-seize compound is used on the HO2S threads. The compound consists of liquid graphite and glass beads. The graphite

tends to burn away, but the glass beads remain, making the sensor easier to remove. New, or service replacement sensors already have the
compound applied to the threads. If the sensor is removed from an exhaust component and if for any reason the sensor is to be reinstalled, the
threads must have anti-seize compound applied before the reinstallation.

If reinstalling the old sensor, coat the threads with anti-seize compound GM P/N 12377953, or equivalent.

8. Install the HO2S.

Tighten the sensor to 42 Nm (31 ft. lbs.).

9. Connect the engine harness electrical connector to the HO2S.

10. Install the oxygen sensor wiring harness heat shield.

Exhaust Crossover Pipe > < Exhaust System - Catalytic Converter Precautions|Page 6487