5. Remove the knock sensor.
INSTALLATION PROCEDURE
1. Install the knock sensor.
NOTE: Refer to Fastener Notice.
IMPORTANT: DO NOT apply thread sealant to sensor threads. The sensor is coated at factory and applying additional sealant will affect the
sensors ability to detect detonation.
Tighten the sensor to 18 N.m (13 lb ft).