buick Workshop Repair Guides

Buick Workshop Service and Repair Manuals

Circuit Testing|Page 8038 > < Circuit Testing|Page 8036
Page 1
background image

Fuse Block: Diagnostic Aids
Testing for Continuity

Testing for Continuity

Caution:  Refer to Test Probe Caution   (See: Service Precautions/Vehicle Damage Warnings/Test Probe Caution).

The following procedures verify good continuity in a circuit.

With a DMM

1. Set the rotary dial of the DMM to the Ohms  position.
2. Disconnect the power feed (i.e. fuse, control module) from the suspect circuit.
3. Disconnect the load.
4. Press the MIN MAX button on the DMM.
5. Connect one lead of the DMM to one end of the circuit to be tested.
6. Connect the other lead of the DMM to the other end of the circuit.
7. If the DMM displays low or no resistance, the circuit has good continuity.

With a Test Lamp

Note:  Only use the test lamp procedure on low impedance power and ground circuits.

1. Remove the power feed (i.e. fuse, control module) from the suspect circuit.
2. Disconnect the load.
3. Connect one lead of the test lamp to one end of the circuit to be tested.
4. Connect the other lead of the test lamp to battery positive voltage.
5. Connect the other end of the circuit to ground.
6. If the test lamp illuminates (full intensity), then the circuit has good continuity.

Circuit Testing|Page 8038 > < Circuit Testing|Page 8036