Lucerne V6-3.9L (2009)
11. Position the fuel feed pipe and harness connector.
12. Connect the EVAP line quick connect fitting (1) to the sender. Refer to Plastic Collar Quick Connect Fitting Service (See: Fuel Line
Coupler/Service and Repair/Plastic Collar Quick Connect Fitting Service).
13. Connect the fuel feed rear pipe quick connect fitting (3) to the sender. Refer to Plastic Collar Quick Connect Fitting Service (See: Fuel Line
Coupler/Service and Repair/Plastic Collar Quick Connect Fitting Service).
14. Connect the fuel level sensor wiring harness electrical connector (4) to the sender.
15. Connect the negative battery cable. Refer to Battery Negative Cable Disconnection and Connection (See: Starting and Charging/Battery/Battery
Cable/Service and Repair).
16. Perform the following procedure in order to inspect for leaks:
1. Turn ON the ignition, with the engine OFF for 2 seconds.
2. Turn OFF the ignition for 10 seconds.
3. Turn ON the ignition, with the engine OFF.
4. Inspect for fuel leaks.
17. Install the fuel sender access hole cover.